The aim of this course is to train you on the manual use of the Draeger 6810 breathalyzer. If you can have the breathalyzer to hand during this section of the course you will gain much more from it.

At the end of this course there is an Assessment test. The assessment will ask you a list of questions all covered in this course. You will need a 90% pass rate to complete the course. Results will be emailed to yourself and your designated manager.

If the results are below 90% you can request a re-sit with your manager who will request one directly from AlcoDigital.

All answers to the questions are covered in the courses so if you are unsure of any you can stop the test at any time and go back to the course. There is no time limit to the course and once complete you will have access to these training documents from one year.

Lessons

AlcoTest 6810 – A brief history of Breathalyzers

Length: 3 minutesComplexity: Easy

Welcome to your Approved Alcohol Testing Officers Course. Before we introduce you to your breath alcohol testing equipment, let's first look at some of the background and history behind the Breathalyzer! The first breathalyzers were developed in 1953 by chemists working for Draeger. They created the beginnings of the device the morning...

AlcoTest 6810 – Blood Alcohol VS Breath Alcohol

Length: 4 minutesComplexity: Hard

Alcohol in the blood (liquid) and alcohol in breath (gas) are two different entities and are therefore measured differently. There is a formula which can be used to establish the…

AlcoTest 6810 – Alcohol Measurements and Readings

Length: 2 minutesComplexity: Easy

As learnt in the last lesson, the measurements for a breath alcohol reading and blood alcohol reading are different, but imply the same level of impairment. BrAC – Breath Alcohol Concentration…

AlcoTest 6810 – The Drink Driving Law

Free Preview

Length: 5 minutesComplexity: Standard

In December 2014, the Drink Driving limit in Scotland was reduced to 22µg of alcohol per 100ml breath. You may also have seen it in the media expressed in its blood…

AlcoTest 6810 – Drink Driving Limits Across Europe

Length: 2 minutesComplexity: Easy

England, Wales, Northern Ireland, and Malta have the highest drink driving limits in all of Europe. Most other European countries not only have a much lower limit, they also have a…

AlcoTest 6810 – Testing in the workplace

Length: 4 minutesComplexity: Easy

So why are you thinking of testing in the workplace?  There are many benefits to screening employees for alcohol use in the work place, including the following: – Safer environment for…

AlcoTest 6810 – Breathalyzer Measurement Conditions

Length: 4 minutesComplexity: Standard

Prior to performing a breath test, there are several factors to consider: Contamination It is imperative to wait at least 20 minutes after smoking, eating or drinking.  Residual mouth contamination…

AlcoTest 6810 – Mouthpieces

Length: 3 minutesComplexity: Easy

  This is the mouthpiece that is used with the Draeger AlcoTest range of breathalysers.  It comes hermetically sealed for hygiene.  There is a brief explanation of the various attributes…

AlcoTest 6810 – Powering your handset

Length: 2 minutesComplexity: Easy

Your Breathalyzer is powered by Alkaline batteries (1.5 V Mignon LR6, AA) and you can expect around 500 tests per set of batteries.  The handset will show a Battery symbol as below…

AlcoTest 6810 – The Breathalyzer

To start, we will look at the components of the AlcoTest 6810 breathalyzer.   If possible, have your breathalyzer to hand and compare with the image below to familiarise yourself with it.…

AlcoTest 6810 – Standard Operation

Length: 5 minutesComplexity: Easy

Follow these steps using your breathalyzer to familiarise yourself. Remember:  Always ensure that there is no residual mouth contamination by waiting at least 15 minutes after eating, drinking or smoking prior…

AlcoTest 6810 – Producing the printout

Length: 5 minutesComplexity: Easy

Having successfully produced your breath test result, you now need to know how to produce the evidential printout. The Draeger Wireless Printer works with multiple devices including the AlcoTest 6810, 6820,…

AlcoTest 6810 – Passive Test

Length: 6 minutesComplexity: Standard

To receive an accurate breath alcohol reading on your breathalyzer, you will use the Automatic sampling method as shown previously.  There are however two other methods of sampling: Passive and Manual Release. Manual release is not applicable…

AlcoTest 6810 – Menu Options

Length: 3 minutesComplexity: Easy

This lesson is best followed with the breathalyzer in hand. Follow the steps in the video to see how you can use the menu options on the 6810 breathalyzer.

AlcoTest 6810 – Calibration & Servicing

Complexity: Easy

The Draeger AlcoTest 6810 is an evidential Breathalyzer with European Approval for Police Use.  Part of the Approval process requires that the accuracy of the handset it checked every 182 days…

AlcoTest 6810 – Summary and Assessment

Length: 10 minutesComplexity: Standard

You have been taken through an introduction to Alcohol Testing with your Draeger 6810 Breathalzyer.  By now you should be familiar with the UK limits, testing practice and use of…

Search for Training Courses